In most cases, the condensate contains oil and solid particulate impurities. If the compressed air condensate is not discharged out of the conveying and application equipment in time, these impurities will diffuse into the whole compressed air system, resulting in problems in operation, increasing production costs and damaging production equipment and products. The important responsibility of the post-treatment equipment is to remove pollutants and water from the compressed air. Leakage and inadequate control are the main reasons for the waste of energy consumption in the post-treatment system.
In the past, when we used the timer to control the discharge solenoid valve, there will also be compressed air loss. Because the timer electromagnetic blowdown valve adopts a rigid timing working mode, it can not control the discharge interval and the accurate timing of opening and closing the valve for useful discharge according to the actual amount of condensate accumulated. When the blowdown valve is opened too often or for too long, a lot of expensive and unused compressed air will immediately leak into the environment, especially in the cold and dry season.
Because the condensate is not generated and accumulated regularly. However, it changes at any time with climate, season, ambient temperature and humidity, daily working hours, loading and unloading conversion and full load rate of the compressor. Only when the condensate is discharged accurately and in real time can unnecessary energy consumption waste and damage be avoided. The high-quality zero gas consumption automatic condensate drain with electronic liquid level control realizes this purpose through capacitive liquid level sensor. The intelligent liquid level electronic control system can effectively avoid the loss of compressed air, discharge the condensate in time, and reduce the demand for input electric energy.